Routine Skin Flash May Not Improve Superficial Dose Accuracy in Nonreconstructed Postmastectomy Radiotherapy Delivered with Volumetric-modulated Arc Therapy under Modern Image-guided Radiotherapy: A Prospective In Vivo Dosimetry Study
In brief
Routine skin flash did not improve dose accuracy in 43 postmastectomy patients
In 43 patients receiving postmastectomy radiotherapy, about 91% of chest-wall dose measurements were within 5% of the prescription, with or without skin flash. Flash raised measured dose by about 1.1% but did not improve accuracy or reduce low-dose readings, and skin toxicity was similar. Omitting routine flash may simplify treatment in this specific setting, but the findings do not address other patient groups.
- Journal
- Practical radiation oncology (Q1)
- Published
- 25 November 2026
- Study design
- Prospective / inception cohort
- Evidence level
- Level 4, Very Low (CEBM 4)
- Authors
- Xuetao Wang, Xin Li, Pengfei Yang, Ling Liu, Feng Peng, Yajie Liu, et al.
- PMID
- 43085658
- DOI
- 10.1016/j.prro.2026.11.017
Why clinicians should know about it
- Picked for Medical Physics (paper of the day, 27 November 2026): Prospective in-vivo VMAT dosimetry evaluates superficial dose and flash
Abstract
PURPOSE: To evaluate the real-world dosimetric effect of skin flash in nonreconstructed postmastectomy radiotherapy (PMRT) delivered using volumetric-modulated arc therapy (VMAT) and determine whether routine skin flash improves superficial dose coverage under modern image-guided radiotherapy (IGRT). METHODS: Consecutive postmastectomy patients enrolled in a prospective observational cohort study received conventional VMAT or VMAT with skin flash (VMAT+Flash). Real-time in vivo dosimetry was performed weekly during the first three weeks using MOSFET detectors at three predefined chest-wall locations. The primary endpoint was the mean absolute percentage deviation from the prescribed dose. Secondary endpoints included the proportion of measurements within ±5% of the prescribed dose, organs-at-risk (OAR) doses, monitor unit (MU) usage, and acute skin toxicity. RESULTS: Forty-three patients (24 VMAT and 19 VMAT+Flash) contributed 387 measurements. Baseline characteristics were balanced between groups. Mean absolute dose deviations were similar between conventional VMAT and VMAT+Flash (2.41% ± 0.56% vs. 2.49% ± 0.63%; P = 0.641). Mixed-effects analysis showed that VMAT+Flash delivered a slightly higher superficial dose (adjusted mean difference, 2.29 cGy; P < 0.001), corresponding to approximately 1.1% of the prescribed 200 cGy dose. The proportion of measurements within ±5% of the prescribed dose was comparable between groups (91.2% vs. 90.1%). This upward shift did not significantly reduce the proportion of measurements below 190 cGy (5.6% vs. 4.1%; P = 0.53) or increase it above 210 cGy (3.2% vs. 5.8%; P = 0.15). No significant differences were observed in acute skin toxicity, OAR doses, or MU; VMAT+Flash showed a numerical increase in contralateral breast dose (706.3 vs. 659.6 cGy; P = 0.061). CONCLUSIONS: In patients receiving nonreconstructed PMRT with modern IGRT, routine skin flash did not improve superficial dose accuracy or acute skin toxicity compared with standard VMAT, suggesting that omission of routine flash simplifies workflow without compromising superficial target coverage in this specific population.
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.