WiseSeg: weakly supervised whole-body PET/CT segmentation of 147 anatomical structures
In brief
WiseSeg scores 0.895 versus 0.884 for TotalSegmentator across 113 PET/CT structures
Tested on 110 PET/CT scans, WiseSeg segmented 147 structures with a mean Dice score of 0.874, finishing each scan in under 120 seconds. For 113 structures, its score modestly exceeded TotalSegmentator's, and it also produced more accurate SUV95 estimates. The study established normal SUV ranges in 98 healthy people, but larger clinical studies are needed to show how useful these tools are in practice.
- Journal
- EJNMMI physics (Q1)
- Published
- 2 September 2026
- Study design
- Retrospective cohort
- Evidence level
- Level 3, Low (CEBM 3b)
- Authors
- Pengxu Wen, Jian He, Lei Qiao, Jing Chen, Lijun Tang, Aimei Li, et al.
- PMID
- 43084133
- DOI
- 10.1186/s40658-026-00934-9
Why clinicians should know about it
- Picked for Medical Physics (paper of the day, 26 November 2026): PET/CT segmentation and SUV quantification validation
Abstract
BACKGROUND: Whole‑body organ segmentation is critical for radiotherapy planning and systemic disease assessment, but existing PET/CT‑tailored segmentation methods suffer from insufficient anatomical coverage, severe annotation bottlenecks, and an unfavorable trade‑off between accuracy and speed, limiting their clinical translation. To address these issues, we developed a weakly supervised framework for whole‑body segmentation of 147 anatomical structures on PET/CT and established normative SUV reference ranges in healthy individuals. METHODS: This retrospective study included 2308 18F‑FDG PET/CT scans from two hospitals and 1746 public CT scans. Model development used 1846 scans for pseudo‑label training (1746 public CT + 100 PET/CT) and 2000 unlabeled PET/CT scans for weakly supervised learning; independent testing used 110 PET/CT scans. A healthy cohort of 98 individuals was included to establish normal SUV reference ranges. An uncertainty‑guided pseudo‑label learning algorithm was trained to segment 147 anatomical structures. Dice scores were calculated between model predictions and expert annotations. Paired t‑tests or Wilcoxon tests with Bonferroni correction were used for statistical analysis. RESULTS: The model achieved a mean Dice score of 0.874 across 147 structures on the test set, with segmentation completed within 120 s per scan. For 113 structures matched to TotalSegmentator, it outperformed TotalSegmentator (0.895 vs. 0.884; P < 0.001). The uncertainty-weighting strategy improved segmentation of small vascular structures (0.702 vs. 0.651; P < 0.001). The model also showed a lower absolute deviation in the 95th-percentile SUV (SUV95; 0.018 vs. 0.021) than TotalSegmentator in PET quantification. Normal SUV reference ranges for 147 structures were established from the healthy cohort. CONCLUSIONS: The proposed weakly supervised framework enables precise and efficient whole-body segmentation of 147 structures on PET/CT. The established normal SUV reference ranges provide a standardized benchmark for quantitative PET/CT interpretation. The source code and pretrained weights are publicly available at https://github.com/Wpx01/WiseSeg .
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.