Low Versus High Intraoperative Intraocular Pressure During Phacoemulsification Cataract Surgery: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
In brief
Low-pressure cataract surgery shows similar outcomes, with 1.5 seconds more ultrasound
In 12 randomized trials involving 1,051 eyes, low- and high-pressure cataract surgery had similar results for vision, corneal health, postoperative pressure, pain, and safety. Low pressure added about 1.5 seconds of ultrasound time, a difference the authors considered clinically negligible; the findings do not establish that the approaches are equivalent.
- Journal
- Journal of clinical medicine (Q1)
- Published
- 3 November 2026
- Study design
- Systematic review / meta-analysis of RCTs
- Evidence level
- Level 1, High (CEBM 1a)
- Authors
- Ahmed Abu-Zaid, Omar A Alnajar, Rashed A Alasoosi, Fawaz Almutairi, Abdullah M Alazemi, Latifah Alyaqout, et al.
- PMID
- 43030700
- DOI
- 10.3390/jcm15218557
Why clinicians should know about it
- Picked for Ophthalmology (top studies of the week, 15 November 2026): Randomized evidence informs intraoperative cataract surgery pressure choices
Abstract
Objective: To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) comparing low versus high intraoperative intraocular pressure (IOP) during phacoemulsification. Methods: PubMed, Scopus, Web of Science (WoS), and CENTRAL were searched from inception through 6 July 2026, followed by a supplementary manual search conducted before data extraction on 5 August 2026, to identify any additional eligible studies. RCTs comparing low-IOP versus high-IOP strategies during phacoemulsification were included. Outcomes were categorized as intraoperative, postoperative, and safety outcomes. Data were pooled as mean differences (MDs) or risk ratios (RRs) with corresponding 95% confidence intervals (CIs) using random-effects models. Results: Twelve RCTs comprising 1051 eyes were included. Cumulative dissipated energy was comparable between low- and high-IOP strategies (MD -0.12, 95% CI -0.45 to 0.20; p = 0.42). No significant between-group differences were observed in endothelial cell density, best-corrected visual acuity, central corneal thickness, or postoperative IOP across the reported follow-up periods (all p > 0.05). Intraoperative pain, aspiration time, total case time, fluid usage, and safety outcomes were also comparable between groups. Low-IOP phacoemulsification was associated with a modest increase in total ultrasound time (MD 1.53 s, 95% CI 0.03 to 3.03; p = 0.047). Conclusions: Low-IOP phacoemulsification provides intraoperative, postoperative, and safety outcomes broadly comparable to high-IOP strategies. Despite a statistically significant but clinically negligible increase in ultrasound time of approximately 1.5 s in favor of low-IOP, no significant differences were observed in cumulative dissipated energy, endothelial cell density, best-corrected visual acuity, central corneal thickness, postoperative IOP, or safety outcomes. However, these findings should not be interpreted as definitive evidence of equivalence or non-inferiority between the two strategies.