Skip to main content

OpenTOPAS-SPECT: an extension for full-physics clinical and preclinical SPECT simulation

In brief

OpenTOPAS-SPECT matched simulation precision 6.9 times faster in one camera setup

The new SPECT simulation tool matched full-transport precision 6.9 times faster in a tested point-source setup, while reproducing absolute sensitivity to within 1%. Across 20 configurations, its faster forced-detection method stayed within 4% of full transport when septa carried up to a fifth of the signal, but undercounted more when septal contribution was higher. Reconstructed-image accuracy remains untested.

Journal
Physics in medicine and biology (Q1)
Published
3 November 2026
Study design
Unclassified
Evidence level
Level 5, Expert Opinion (CEBM 5)
Authors
Victor Valladolid Onecha, Alejandro Bertolet
PMID
42976452
DOI
10.1088/1361-6560/aebd36

Why clinicians should know about it

  • Picked for Medical Physics (paper of the day, 6 November 2026): SPECT simulation benchmarked against measurements and analytic references

Abstract

Single-photon emission computed tomography (SPECT) simulations must resolve collimator transport, detector energy deposition, and low-efficiency projection formation within one model. General transport codes leave users to build the imaging components, whereas dedicated SPECT codes offer efficient camera models with less freedom to represent new systems. We developed OpenTOPAS-SPECT to bring projection-domain SPECT simulation into the declarative parameter-file workflow of OpenTOPAS.
Approach: We added parametric parallel-hole, converging, pinhole, multi-pinhole, and slit-slat collimators; sodium-iodide and cadmium-zinc-telluride detector configurations; energy-resolved and forced-detection scorers; native decay-chain sources; and an evidence-graded library of 14 camera presets. We tested preset construction, multi-view consistency, and variance reduction, and benchmarked projection-domain quantities against measured, independent-code, and analytic references.
Main results: At 140.5 keV and 10 cm from the collimator face, the Siemens Symbia low-energy high-resolution configuration gave 7.49 × 10-5 counts per decay, or 0.82 of the measured 9.1 × 10-5. GE collimator sensitivities were 1.08 to 1.15× the SIMIND range midpoints, while the 364.5 keV low-to-high-energy sensitivity ratio was 59.5 versus 67.7. Planar point-spread widths were 4% to 9% below analytic geometric resolution from 5 to 30 cm. In this Symbia LEHR point-source geometry, forced detection reached matched precision 6.9× faster than full transport and reproduced its absolute sensitivity to 1% without calibration. Across 20 configurations (five collimators, 113 keV to 1 MeV), forced detection stayed within 4% of full transport while septa carried up to a fifth of the signal, but fell 7% to 25% below it where they carried 25% or more. The release-gating suite ran all 23 example decks and built all 14 presets.
Significance: OpenTOPAS-SPECT provides reusable SPECT components within the OpenTOPAS parameter system, with bounded projection-domain benchmarks for the first stable public release. The evidence supports the tested configurations and observables; reconstructed-image accuracy and broader system coverage remain untested.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.