Skip to main content

Dimensionality reduction for partial-volume correction in quantitative SPECT

In brief

Region-perturbed correction cut mean SPECT activity errors to 0% to 4% in phantoms

In simulations of eight anthropomorphic phantoms, region-perturbed correction brought mean activity-concentration errors for tumors, kidneys, and spleen down from 7% to 23% before correction to 0% to 4%. The approach relaxes the assumption that activity is uniform within each region, but evidence comes mainly from simulations, with only two example patients.

Journal
Physics in medicine and biology (Q1)
Published
19 October 2026
Study design
Unclassified
Evidence level
Level 5, Expert Opinion (CEBM 5)
Authors
Johan Gustafsson, Erik Larsson, Katarina Sjogreen-Gleisner
PMID
42896599
DOI
10.1088/1361-6560/aeb644

Why clinicians should know about it

  • Picked for Medical Physics (top studies of the week, 25 October 2026): Region‑perturbed deconvolution reduces activity‑concentration errors

Abstract

OBJECTIVE: The aim of this paper is to develop a method for region-based post-reconstruction partial-volume correction (PVC) of SPECT images, which explicitly estimates the mean activity concentration in regions without assuming strict intra-regional uniformity. APPROACH: Partial-volume correction was applied to177Lu-SPECT images obtained from the simulation of eight anthropomorphic phantoms as well as two example patients. Both sets of data were reconstructed using OS-EM with ten subsets and up to 40 iterations, including compensation for attenuation, scatter, and spatial resolution. Reconstructed images were deconvolved using the van Cittert algorithm and Lucy-Richardson algorithm, both implemented on images represented as standard cuboid voxels or as regional voxels, consisting of regions defined from whole-image segmentation. Methods embedding regional voxels were applied both assuming region-wise uniform activity concentration and incorporating perturbations in the form of cosine series to relax the uniformity assumption. For comparison, images were also processed with the iterative Yang method and MIRD recovery coefficients. Evaluation was performed with respect to the estimated activity concentration for kidneys, spleen, and tumours, as well as the total activity in the images. MAIN RESULTS: Mean activity-concentration errors prior to PVC were (-22.6±11.5) %, (-13.8±2.1) %, and (-7.4±2.8) % for tumours, kidneys, and spleen, respectively. Region-perturbed van Cittert deconvolution with order 4 reduced these errors to (2.3±7.7) %, (0.3±2.2) %, and (4.0±1.6) % while the errors for region-perturbed Lucy-Richardson deconvolution of order 4 were (0.3±8.0) %, (0.0±1.6) %, (2.6±0.5) %. Corresponding results for the iterative Yang method were (2.8±21) %, (-0.3±2.1) %, and (3.8±2.4) % and using MIRD recovery coefficients (-5.0±14.2) %, (-7.1±1.9) %, and (-0.6±3.1) %. SIGNIFICANCE: Region-based PVC improves the accuracy of quantitative SPECT, and the inclusion of cosine perturbations allows for a gradual relaxation of the uniformity assumption.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.