DuDoTransGAN: Dual-Domain transformer based generative adversarial unsupervised network for metal artifact reduction in paired and unpaired CT
In brief
DuDoTransGAN gets radiologists' top pick in 45% of knee CT comparisons
In a retrospective evaluation, this unsupervised method for reducing metal artifacts had the highest radiologist selection rate on clinical knee CT scans: 45%, versus 2% to 21% for other unsupervised methods. It also scored highest on four of five image-quality measures, but the study did not test whether improved images change diagnosis or patient care.
- Journal
- European journal of radiology (Q1)
- Published
- 8 October 2026
- Study design
- Cohort / observational study
- Evidence level
- Level 3, Low (CEBM 3b)
- Authors
- Yan Wang, Jia Deng, Zhaojie Peng, Yule Zeng, Jikang Jiang, Langtao Zhou, et al.
- PMID
- 42863450
- DOI
- 10.1016/j.ejrad.2026.113289
Why clinicians should know about it
- Picked for Medical Physics (paper of the day, 14 October 2026): Dual‑domain GAN for metal artifact reduction in CT
Abstract
PURPOSE: Metal artifacts from implants degrade CT image quality, while supervised metal artifact reduction (MAR) methods require paired clean data that are rarely available clinically. METHODS: In this retrospective study, we developed DuDoTransGAN, an unsupervised dual-domain generative adversarial network for paired and unpaired training. It was evaluated on a publicly available paired synthetic dataset (SYN; 90,000 training and 2,000 test slices) and a clinical unpaired knee CT dataset (KNE; 19,032 slices from 66 patients; mean age, 55.8 ± 16.1 years; 36 males), including 6,168 slices with metal artifacts. On KNE, two radiologists independently assessed five image-quality aspects using Likert scales, with ratings reviewed by a senior radiologist. RESULTS: In the paired SYN experiment, DuDoTransGAN achieved a mean PSNR of 38.19 dB, the highest mean SSIM (0.975), and the lowest mean RMSE (5.65) among unsupervised methods. Performance remained stable with increasing metal-mask size, demonstrating robustness under larger-metal-mask conditions. In the unpaired KNE experiment, inter-rater agreement was excellent (ICC, 0.941). DuDoTransGAN achieved the highest mean scores among unsupervised methods for artifact removal (3.87 ± 0.48), diagnostic value (3.75 ± 0.50), visual effect (3.90 ± 0.36), and detail retention (3.96 ± 0.40), together with a comparable sharpness score (3.87 ± 0.58), and the highest radiologist selection rate (45 % vs 2 %-21 %). CONCLUSION: DuDoTransGAN is an adaptable unsupervised dual-domain MAR framework that performs effectively on paired synthetic and unpaired clinical data, producing high-quality, clinically interpretable CT images in the presence of metallic implants.
Abstract as published, via PubMed.