Assessment of image quality and feasibility of Photon-Counting detector CT for the Non-Contemporaneous follow-up of intracranial aneurysms treated with flow diverter stents
- Journal
- European journal of radiology (Q1)
- Published
- 31 August 2026
- Study design
- Prospective / inception cohort
- Evidence level
- Level 4, Very Low (CEBM 4)
- Authors
- Jiang-Ping Gao, Yang Bian, Rong-Ju Zhang, Xin-Feng Liu, Xiao-Hui Wang, Bin Lv, et al.
- PMID
- 42691745
- DOI
- 10.1016/j.ejrad.2026.113203
Why clinicians should know about it
- Picked for Medical Physics (top studies of the week, 6 September 2026): PCD-CT provides superior stent lumen visualization
Abstract
BACKGROUND: Noninvasive imaging is essential for long-term surveillance of flow diverter-treated intracranial aneurysms. We evaluate the image quality and feasibility of photon-counting detector CT (PCD-CT) in a real-world, non-contemporaneous follow-up setting, comparing it with intraoperative baseline DSA and flat-panel detector CT (VasoCT). METHODS: This retrospective cohort study included 30 patients (32 aneurysms) followed with PCD-CT (median: 6.5 months) after flow diverter treatment. Three neurointerventionalists, blinded to clinical data, assessed stent lumen visibility and diagnostic confidence using a 5-point Likert scale. Quantitative metrics included signal-to-noise ratio, contrast-to-noise ratio, relative metal artifact width, and radiation doses. A mixed linear model identified predictors of image quality. RESULTS: PCD-CT stent lumen visibility (4.6 ± 0.7) was significantly higher than baseline DSA (3.0 ± 0.5, P < 0.001) and VasoCT (3.1 ± 1.2, P < 0.001). Diagnostic confidence scores were significantly higher for DSA (5.0 ± 0.0) and PCD-CT (4.8 ± 0.6) than for VasoCT (3.4 ± 1.0, both P < 0.001), while PCD-CT was slightly but significantly lower than DSA (P = 0.031). Inter-observer agreement was excellent (ICC ≥ 0.945). PCD-CT effective dose (0.79 ± 0.07 mSv) was higher than localized DSA (0.13 ± 0.02 mSv) and VasoCT (0.55 ± 0.08 mSv) due to whole-brain coverage. Mixed model identified PCD-CT as the strongest positive predictor for lumen visibility (β = 1.65, P < 0.001), and this advantage remained robust across different aneurysm morphologies and the predominant stent designs evaluated in this cohort. CONCLUSION: PCD-CT provides superior stent lumen visualization compared to baseline imaging, while maintaining a sub-millisievert radiation dose. It represents a promising non-invasive surveillance tool, though prospective validation of its diagnostic accuracy for in-stent stenosis is required.
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.