Improved detection of endovascular stent fractures with photon counting computed tomography: A phantom study

Journal
European journal of radiology (Q1)
Published
31 July 2026
Study design
Unclassified
Evidence level
Level 5, Expert Opinion (CEBM 5)
Authors
Yiheng Tan, Weihao Li, Richard Haitsma, Jan Braaksma, Jean-Paul P M De Vries, Mathias Prokop, et al.
PMID
42580077
DOI
10.1016/j.ejrad.2026.113121

Why clinicians should know about it

Abstract

OBJECTIVE: To evaluate the ability of photon-counting detector computed tomography (PCD-CT) to detect visceral endovascular stent fractures compared to EID-CT, and to assess its impact on subjective image quality and quantitative image characteristics. METHODS: Five identical balloon-expandable covered stents were placed in an abdominal phantom and scanned using a PCD-CT (Naeotom Alpha) and an EID-CT scanner (Somatom Force, Siemens Healthineers). PCD-CT images were reconstructed using two slice thickness (0.2 mm: ultra-high resolution [UHR]; 0.4 mm: standard resolution [SR]) and both medium sharp (Br56) and sharp kernel (Br72). 1024 matrix were applied in UHR reconstructions, while both 512 and 1024 matrix were used in SR reconstructions. EID-CT images were reconstructed using medium sharp kernel (Br59) with 512 matrix. Stents were scanned intact and then sequentially fractured from Type 1 (single strut) to Type 4 (complete transverse fracture with displacement). Two independent readers assessed diagnostic accuracy and image quality, while an automatic algorithm evaluated strut sharpness, blooming, and noise levels. RESULTS: PCD-CT significantly improved stent fracture detection, with the highest overall diagnostic accuracy achieved by PCD-CTUHR-Br72 (96 %) and PCD-CTSR-Br72 with 1024 matrix (92 %), compared to PCD-CTSR with 512 matrix and EID-CT (50 %-56 %). PCD-CTBr72 identified more than 80 % of Type 1 and Type 2 fractures, whereas neither PCD-CTSR with 512 matrix nor EID-CT detected any single-strut fractures. PCD-CTBr72 with 1024 matrix also provided superior image quality, enhanced sharpness, and reduced blooming artifacts (all p < 0.001). CONCLUSIONS: PCD-CTBr72 with 1024 matrix significantly enhances the detection of visceral endovascular stent fractures, particularly single-strut fractures that remain undetectable on EID-CT.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.