Skip to main content

No Significant Clinical Difference Detected Between Zero and Seven Degrees of Targeted Posterior Tibial Slope Cut in Total Knee Arthroplasty: A Within-Person Simultaneous Bilateral Randomised Controlled Trial

In brief

In 70 patients, 7-degree tibial slope showed no five-year clinical advantage

In this randomized bilateral trial, each of 70 patients received one knee targeted to 0 degrees and the other to 7 degrees of posterior tibial slope. At five years, range of motion, knee scores, satisfaction and implant survival were similar; the study found no clinical advantage, but does not establish that the approaches are equivalent.

Journal
Orthopaedics & traumatology, surgery & research : OTSR (Q1)
Published
25 November 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Daniel Wai-Yip Wong, Jacky Chi-Kit Chan, Yiu Chung Wong, Qunn Jid Lee, Kenneth Wing-Kin Law, Wing Lok Kam
PMID
43085539
DOI
10.1016/j.otsr.2026.105036

Why clinicians should know about it

  • Picked for Orthopedics and Sports Medicine (paper of the day, 26 November 2026): Bilateral randomized trial informs posterior slope in total knee arthroplasty

Abstract

BACKGROUND: The biomechanical advantages of increasing posterior tibial slope (PTS) are well established in vitro, yet clinical evidence linking PTS to functional outcomes remains inconsistent. Inter-individual variability in conventional study designs may confound evaluation of the isolated effect of PTS. This within-person bilateral randomised controlled trial aimed to determine whether a targeted 7° PTS confers superior clinical outcomes compared with a targeted 0° PTS in posterior-stabilised total knee arthroplasty (TKA). MATERIALS AND METHODS: Seventy patients with bilateral primary knee osteoarthritis underwent simultaneous bilateral TKA. One knee was randomly assigned to receive a targeted 0° PTS and the contralateral knee a targeted 7° PTS, using identical implants and a standardised measured resection technique with computer navigation. The primary outcome was maximum passive flexion and extension range of motion (ROM) at five years. Secondary outcomes included Knee Society Score (KSS), patient satisfaction (0-10 scale), and aseptic implant survival. Patients were followed for five years. RESULTS: Mean achieved PTS was -1.0° (range -7.9° to 4.7°) in the 0° targeted group and 6.4° (range 1.8° to 9.7°) in the 7° targeted group (p < 0.001). A resultant anterior slope occurred in 37.1% of knees in the 0° group versus none in the 7° group (p < 0.001). At five years, no statistically significant differences were observed for flexion, extension, KSS, or satisfaction score. Aseptic implant survival was 100% in both groups. CONCLUSION: In this within-person simultaneous bilateral RCT, no significant clinical differences in ROM, KSS, satisfaction score, or aseptic implant survival were detected between knees targeted at 0 ° and 7 ° PTS at five-year follow-up. LEVEL OF EVIDENCE: II.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.