Divergent morphology of the transforaminal safety zone in degenerative spondylolisthesis: a 3D MRI/CT fusion study
In brief
Greater spinal slip flattens the simulated transforaminal safety zone
In 60 patients, greater L4 vertebral slip was associated with a shorter, smaller simulated safety zone at L4/5, while slip percentage correlated with slightly greater width. Width did not differ significantly across the three slip groups. This retrospective imaging study maps a possible anatomical change, but whether it affects surgical safety or outcomes remains unknown.
- Journal
- European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society (Q1)
- Published
- 24 November 2026
- Study design
- Cross-sectional study
- Evidence level
- Level 3, Low (CEBM 3b)
- Authors
- Katsuhisa Yamada, Ken Nagahama, Yoshinao Koike, Yoshinori Hyugaji, Tomohiro Miyashita, Tomoya Sato, et al.
- PMID
- 43076961
- DOI
- 10.1007/s00586-026-10512-3
Why clinicians should know about it
- Picked for Anatomy (paper of the day, 26 November 2026): 3D imaging quantifies spinal surgical safety-zone morphology
Abstract
PURPOSE: The transforaminal (TF) approach through Kambin's triangle is the cornerstone of minimally invasive spinal surgery. Although degenerative lumbar spondylolisthesis (DS) is a common indication, its quantitative effect on the three-dimensional (3D) anatomy of the safety zone remains unclear. We aimed to evaluate the 3D morphological alterations of the TF safety zone in DS using magnetic resonance imaging (MRI)/computed tomography (CT) fusion imaging. METHODS: In this exploratory retrospective imaging study, we analysed 60 patients who underwent lumbar 3D MRI/CT fusion imaging categorised into three groups (n = 20 each): no-slip, Meyerding grade 1, and grade 2 spondylolisthesis. Using a validated 3D MRI/CT fusion model, we evaluated a standardized 45° simulated transforaminal trajectory at the L4/5 level, and bilaterally measured the simulated safety-zone width (horizontal distance from the superior articular process [SAP] to the exiting nerve root), height (inter-endplate distance), and area. RESULTS: Mixed-effects analyses showed that greater vertebral slip was associated predominantly with reduced safety-zone height and area, whereas categorical group differences in width were not significant. In patient-level correlation analyses, L4 vertebral slip percentage was positively correlated with safety-zone width (r = 0.257, p = 0.048) and negatively correlated with height (r = -0.669, p < 0.001). The total area demonstrated a significant negative correlation with slip percentage (r = -0.400, p = 0.002). CONCLUSIONS: The 3D morphology of the standardized simulated TF safety zone demonstrated a divergent morphometric pattern associated with greater L4 vertebral slip percentage, characterized predominantly by reduced vertical height together with relatively greater horizontal width, resulting in a flatter safety-zone profile. These exploratory cross-sectional findings provide relevant anatomical information for evaluating the transforaminal corridor in patients with DS.
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.