Skip to main content

A multi-class gastric biopsy artificial intelligence model developed from whole slide histopathological images

In brief

Gastric biopsy AI reached 96% sensitivity and 95% specificity externally

Tested across six centers, the six-class model achieved 96.1% sensitivity and 95.0% specificity in external cohorts; in prospective testing, it reached 93.4% sensitivity and 99.0% specificity. It also improved nine pathologists' accuracy and cut diagnostic time, but its external performance for distinguishing early from advanced cancer and predicting lymph node spread was more modest, leaving those uses to validate further.

Journal
NPJ digital medicine (Q1)
Published
8 August 2026
Study design
Prospective / inception cohort
Evidence level
Level 2, Moderate (CEBM 2b)
Authors
Jian-Ning Chen, Chang Zhao, Hui Chen, Jian-Xiong Gu, Qin-Yue Yao, Rui Chen, et al.
PMID
43073313
DOI
10.1038/s41746-026-03102-6

Why clinicians should know about it

Abstract

Pathological diagnosis of biopsies remains the gold standard for gastric diseases such as gastric carcinoma (GC), but it suffers from clinical misdiagnosis and high workload. Accurately distinguishing early-stage GC (EGC) from advanced-stage GC (AGC) and preoperatively predicting lymph node metastasis (LNM) are crucial for precise treatment; however, this remains a challenge in biopsies. To address these challenges, we retrospectively collected 20,711 whole-slide images (WSIs) from 17,086 patients across six centers and prospectively enrolled 3698 WSIs from 2965 patients to develop and validate a gastric biopsy artificial intelligence model (GBAIM), which performed six-class classification on WSIs. GBAIM achieved 96.1% sensitivity and 95.0% specificity in external cohorts, and 93.4% and 99.0% in the prospective cohort, respectively, demonstrating excellent performance and strong generalization ability. GBAIM enhanced the performance of all nine pathologists in auxiliary diagnostic experiments, raising their accuracy by 1.7%-39.0%, while reducing diagnostic time by 29.4%-50.5%. Besides, the fine-tuned GBAIM-T, which aims to differentiate EGC from AGC, achieved an AUC of 0.907 and 0.826 on internal and external testing sets, respectively, and GBAIM-N, which aims to predict LNM, achieved an AUC of 0.814 and 0.706 on internal and external testing sets, respectively. Taken together, GBAIM is a valuable tool in clinical practice.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.