Skip to main content

Risk of reoperation for recurrence after penetrating versus non-penetrating mesh fixation in laparoscopic primary groin hernia repair: a nationwide register-based cohort study

Journal
Surgical endoscopy (Q1)
Published
21 November 2026
Study design
Prospective / inception cohort
Evidence level
Level 2, Moderate (CEBM 2b)
Authors
Rancke-Madsen P, Baker JJ, Rosenberg J, Öberg S
PMID
43067629
DOI
10.1007/s00464-026-13544-4

Why clinicians should know about it

  • Picked for Surgery (paper of the day, 23 November 2026): Large comparative cohort informs mesh fixation in laparoscopic hernia repair

Abstract

BACKGROUND: Mesh fixation is widely used in laparoscopic transabdominal preperitoneal (TAPP) groin hernia repair. However, due to insufficient evidence, clear recommendations on the optimal mesh fixation method are lacking. The aim of this study was to compare penetrating versus non-penetrating mesh fixation in laparoscopic TAPP repair for groin hernia with respect to the risk of reoperation for recurrence. METHODS: This nationwide register-based cohort study used prospectively collected data from the Danish Hernia Database from January 1998 to May 2025. Adults undergoing elective TAPP repair for groin hernia with either penetrating (tacks, staples, or sutures) or non-penetrating (glue or self-adhesive mesh) mesh fixation were included. Five cohorts were assessed: lateral, medial, pantaloon, femoral, and combined hernias. The primary outcome was reoperation for recurrence, analysed with multivariable Cox proportional hazard regression adjusted for age and sex. RESULTS: A total of 66,708 groins were included. Compared with penetrating fixation, non-penetrating fixation was associated with lower reoperation rates in lateral (7% vs 3%; HR 0.56, 95% CI 0.50-0.62), medial (6% vs 3%; HR 0.70, 95% CI 0.61-0.81), and pantaloon hernias (8% vs 3%; HR 0.50, 95% CI 0.35-0.72). No significant difference was observed for femoral hernias (2% vs 1%; HR 0.66, 95% CI 0.32-1.35). CONCLUSION: The reoperation rate was significantly lower after TAPP repair when using non-penetrating mesh fixation in lateral, medial, and pantaloon hernias compared with penetrating mesh fixation.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.