Skip to main content

Predictive performance of bedside physiological parameters for the failure of prophylactic non-invasive ventilation after extubation

In brief

Airway occlusion pressure identified reintubation risk better than routine bedside measures

In 60 high-risk adults receiving preventive noninvasive ventilation after extubation, 14 required reintubation within seven days. Airway occlusion pressure distinguished those who failed better than respiratory rate, oxygenation, tidal volume, and the ROX index, but performed similarly to measures of inspiratory effort; external validation is needed before clinical use.

Journal
Critical care (London, England) (Q1)
Published
11 November 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Francesco Murgolo, Domenico Luca Grieco, Michele Bertoni, Alessandro Cardu, Tommaso Pettenuzzo, Salvatore M Maggiore, et al.
PMID
43065113
DOI
10.1186/s13054-026-06453-4

Why clinicians should know about it

Abstract

BACKGROUND: Extubation failure is associated with increased mortality. Whether bedside physiological variables can identify patients at risk of reintubation during prophylactic NIV after extubation is unknown. METHODS: In this post hoc analysis of a multicenter physiological study, 60 hypoxemic adults at high risk of extubation failure underwent two 1-hour NIV sessions after planned extubation, with oronasal and full-face masks in randomized crossover order. We assessed the magnitude of airway occlusion pressure (Pocc), the esophageal pressure swing (ΔPes), SpO₂/FiO₂, respiratory rate, tidal volume, dynamic lung elastance (EL,dyn), ROX index [(SpO₂/FiO₂)/respiratory rate] and the pressure-oxygenation index (POX, SpO₂/FiO₂ divided by Pocc). Prophylactic NIV failure was reintubation for respiratory failure within 7 days. Discrimination was assessed by ROC analysis. RESULTS: Fourteen patients (23%) experienced NIV failure. Pocc yielded areas under the curve (AUCs) of 0.83 (95% CI, 0.71-0.95) with the oronasal mask and 0.83 (95% CI, 0.72-0.95) with the full-face mask, showing greater discriminative performance than tidal volume (AUCs, 0.55 and 0.53), respiratory rate (0.54 and 0.38), SpO₂/FiO₂ (0.51 and 0.50), and the ROX index (0.54 and 0.38; all p < 0.05). By contrast, the discriminative performance of Pocc did not differ from that of EL,dyn (AUCs, 0.72 and 0.73; p = 0.08 and 0.11), POX (AUCs, 0.82 and 0.81; p = 0.68 and 0.29), or |ΔPes| (AUCs, 0.83 and 0.82; p = 1.00 and 0.64). CONCLUSIONS: During prophylactic NIV, Pocc discriminated NIV failure better than conventional bedside variables, with no detectable difference from directly measured inspiratory effort. External validation is required.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.