Skip to main content

Anatomic Evaluation of Sacroiliac Joint Dimensions: A Computed Tomography Imaging Series to Define Recommended Parameters for Lateral Fusion

In brief

CT scans show sacroiliac fusion corridor distance falls to 16.8 mm at S2

In CT scans of 260 sacroiliac joints, the mean distance from the S2 level to the lateral foramen was 16.8 mm, compared with 21.7 mm at S1. Sex and atypical lumbosacral anatomy also shaped measurements, but variation within groups was greater than differences between them; whether tailoring implants or planning to these dimensions improves surgical safety remains unknown.

Journal
International journal of spine surgery (Q1)
Published
20 November 2026
Study design
Retrospective cohort
Evidence level
Level 3, Low (CEBM 3b)
Authors
Usman Latif, Christopher M Lam, Sarah A Keim, Nicholas Wharton, Marcel Dreischarf, Kara Ashcraft, et al.
PMID
43064537
DOI
10.14444/8995

Why clinicians should know about it

  • Picked for Anatomy (paper of the day, 22 November 2026): CT morphometry defines SIJ anatomy and a surgical safe corridor

Abstract

BACKGROUND: Sacroiliac joint (SIJ) dysfunction is a frequent yet underrecognized cause of low back pain, accounting for up to 30% of cases of nonradicular back pain. Minimally invasive lateral SIJ fusion enables faster recovery than traditional posterior open techniques but risks adjacent neurovascular injury, particularly with implant malposition. Despite rising procedural volume, the anatomical limits of the lateral fusion corridor remain poorly defined. OBJECTIVE: This study quantifies sacroiliac morphology in typical and atypical anatomy to assess how vertebral anomalies affect the lateral corridor, and the safety of minimally invasive SIJ fusion. METHODS: A retrospective computed tomography-based morphometric analysis of 260 joints from 130 patients was performed to define safe surgical corridors and examine variability by gender and presence of atypical anatomy at the lumbosacral junction. Measurements included iliac length, SIJ gap, and distance to the lateral foramen (ilioforaminal length [IFL] and sacroforaminal length [SFL]). RESULTS: A total of 260 SIJs from 130 patients (66 men, 64 women; mean age, 58.6 years) were analyzed, of whom 84 (65%) had typical and 46 (35%) had atypical anatomy. In the overall cohort, all 4 measured parameters differed significantly between the S1 and S2 levels, with smaller values observed at S2 (P < 0.01). As representative measures of the lateral fusion corridor, mean (SD) SFL was 21.7 (3.8) mm at S1 and 16.8 (3.9) mm at S2, whereas the mean IFL measured 43.9 (5.1) mm at S1 and 32.8 (5.9) mm at S2. Men demonstrated significantly shorter SFL at S1 (P < 0.05) and S2 (P < 0.01). Women exhibited significantly shorter iliac lengths (P < 0.01) and significantly larger SIJ gaps (P < 0.01) than men at both S1 and S2. Atypical anatomy was associated with significantly shorter SFL and iliac lengths at S2 (both P < 0.05) and with reduced IFL at S1 (P < 0.05) and S2 (P < 0.01) compared with typical anatomy. CONCLUSIONS: SIJ dimensions differed significantly by sex and atypical lumbosacral anatomy, although within-group variation exceeded between-group differences. CLINICAL RELEVANCE: These differences may influence patient-specific surgical planning and safe implant insertion limits, while preoperative computed tomography planning and anatomically adaptive device design may improve procedural safety and success.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.