Skip to main content

Clinical efficacy of a patient-specific 3D-printed reduction brace for tibial shaft fractures: a prospective randomized controlled trial

In brief

A 3D-printed brace strategy cut tibial fracture surgery time by 19 minutes

In this 30-patient randomized trial, the brace-based fixation strategy took about 19 minutes less than intramedullary nailing and also involved less blood loss and fewer fluoroscopy exposures. Early pain and time to documented healing were lower or shorter, but 3-month function did not differ; the small, short trial cannot establish the brace's independent benefit.

Journal
Frontiers in medicine (Q1)
Published
4 November 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Xiaohui Teng, Yidan Yang, Weize Zhang, Yingjie Zhu, Leilei Zhang, Youwen Liu
PMID
43054460
DOI
10.3389/fmed.2026.1960596

Why clinicians should know about it

Abstract

PURPOSE: To preliminarily compare the perioperative and short-term clinical outcomes of a patient-specific 3D-printed reduction brace-based fixation strategy and conventional intramedullary nailing for tibial shaft fractures. METHODS: This single-center prospective randomized controlled trial included 30 patients with closed AO/OTA type 42 tibial shaft fractures enrolled between September 2025 and February 2026. Follow-up data available through June 24, 2026, were included in the present analysis. Patients were randomly assigned using a random number table to either the patient-specific 3D-printed reduction brace group (n = 15) or the intramedullary nail group (n = 15). Due to loss to follow-up, 13 patients in the 3D-printed reduction brace group and 15 patients in the intramedullary nail group completed the prespecified 3-month clinical assessment. Operative time, intraoperative fluoroscopy frequency, blood loss, postoperative Visual Analog Scale (VAS) scores, time to first documented healing, functional outcomes, and complications were compared between groups. Perioperative and 1-week outcomes were analyzed in all 30 randomized participants. Healing and other later follow-up outcomes were analyzed using available cases according to randomized allocation; a censored time-to-event analysis retained all randomized participants as a sensitivity analysis. RESULTS: Operative time was shorter in the brace group by 18.80 minutes (95% CI, 11.21-26.39 minutes), with 1.60 fewer fluoroscopic exposures (95% CI, 0.87-2.33) and 37.87 mL less intraoperative blood loss (95% CI, 23.39-52.34 mL). The 1-week VAS score was lower (Hodges-Lehmann shift, -1.00; 95% CI, -2.00 to -1.00). Among the 28 participants with follow-up data, time to first documented healing was shorter in the brace group (Hodges-Lehmann shift, -2.00 weeks; 95% CI, -2.00 to -1.00 weeks). No statistically significant between-group differences were observed in residual fracture-site displacement classification or 3-month Johner-Wruhs functional outcomes. Sensitivity analyses did not materially change the conclusions. CONCLUSIONS: In this small exploratory trial, the brace-based fixation strategy was associated with more favorable perioperative outcomes, less early postoperative pain, and shorter time to first documented healing than intramedullary nailing. However, these preliminary findings compare two different fixation strategies and do not establish the independent clinical superiority of the 3D-printed brace. Larger multicenter studies with longer follow-up are warranted. TRIAL REGISTRATION: The study was registered with the International Standard Randomised Controlled Trial Number (ISRCTN) registry (ISRCTN10781625). The trial registration record is available at https://www.isrctn.com/ISRCTN10781625.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.