Diagnostic accuracy of imaging techniques for aseptic loosening in total hip arthroplasty; a systematic review
In brief
Review finds no imaging test reliably diagnoses loose hip replacements
A review of 11 studies found no imaging approach reliable enough to recommend for detecting aseptic loosening after hip replacement. Dual-energy CT and motion-based CT had the strongest reported results, but these came from single-centre studies, and all included studies had high risk of bias. Better blinded research is needed before advanced scans can guide revision decisions.
- Journal
- Hip international : the journal of clinical and experimental research on hip pathology and therapy (Q1)
- Published
- 18 November 2026
- Study design
- Systematic review / meta-analysis of RCTs
- Evidence level
- Level 1, High (CEBM 1a)
- Authors
- Alon G M Hopman, Leendert Blankevoort, Esmee H J Van Alebeek, Inger N Sierevelt, Olivier P P Temmerman, Faridi S Jamaludin, et al.
- PMID
- 43053279
- DOI
- 10.1177/11207000261491642
Why clinicians should know about it
- Picked for Radiology, Radiation Oncology, Nuclear Medicine, Medical Physics and Imaging (top studies of the week, 22 November 2026): Systematic review compares imaging accuracy against operative findings
Abstract
BACKGROUND: As the number of total hip arthroplasties (THAs) performed worldwide increases, the burden of revision surgery rises, with aseptic loosening being a leading cause. Diagnostic imaging strategies remain suboptimal, potentially leading to unnecessary revision or undertreatment. This systematic review aimed to compare the diagnostic accuracy of imaging modalities for detecting aseptic loosening in THA, using intraoperative findings as the reference standard. METHODS: This PRISMA-compliant systematic review included a search in PubMed, Embase, and the Cochrane Library. Eligible studies included adult patients with suspected aseptic loosening of THA, comparing at least one imaging modality to the intraoperative finding. Risk of bias was assessed using the QUADAS-2 tool. Diagnostic performance metrics were extracted or calculated. RESULTS: The search and selection yielded 11 articles. Imaging modalities included plain radiography, CT-scans, SPECT/CT, FDG-PET, bone scintigraphy, arthrography, and MRI. Risk of bias was high in all studies, primarily related to patient selection and applicability of the reference standard. The overall certainty of evidence ranged from low to moderate. Dual-energy CT and inducible motion CT showed the highest reported diagnostic performance, based on single-centre studies. CONCLUSIONS: All included studies demonstrated a high risk of bias, and surgeons were not blinded at the time of revision surgery. As a result, no reliable diagnostic strategy can currently be recommended. The favorable findings for CT-based techniques are hypothesis-generating. Methodologically robust, double-blinded studies are required to determine the true accuracy of advanced imaging techniques.PROSPERO registration number:CRD42024584480.
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.