Skip to main content

Evaluation of the accuracy of zygomaticomaxillary complex fracture reduction and fixation using a fully digital workflow versus conventional protocol: a randomized clinical trial

In brief

Digital guides reduced zygomatic fracture alignment error by 1 mm

In a randomized trial of 28 patients, digital guides and custom plates brought fracture alignment to an average of 0.29 mm from the planned position, compared with 1.29 mm using conventional surgery. Patients in the digital group also reported greater aesthetic satisfaction and had shorter operations, but numbness rates were similar; the small trial leaves results to confirm in larger studies.

Journal
Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery (Q1)
Published
18 November 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Dina Ayman Fayek, Mohamed Mounir, Sameh Tarek Mekhemer
PMID
43050964
DOI
10.1016/j.jcms.2026.109958

Why clinicians should know about it

Abstract

The zygomatic bone has multiple points of articulation with the craniofacial skeleton, and accurate intraoperative reduction in various planes is very challenging and entirely dependent on the operator's subjective evaluation. This study aimed to investigate the efficiency of a novel fully digital protocol versus the conventional management strategy for zygomaticomaxillary complex fracture reduction and fixation. Twenty-eight patients with acute zygomatic fractures who met the inclusion criteria were recruited; each group of 14 patients was randomly assigned. The intervention group received a fully digital protocol, represented by customized predictive-hole surgical guides and patient-specific fixation plates, while the control group was managed conventionally. Accuracy of bone reduction was the primary outcome. The results showed that, when comparing the virtual reduction of both groups with the postoperative CT scans, the overall accuracy was markedly higher in the digital group (0.290 ± 0.132 mm) than in the conventional group (1.290 ± 0.525 mm), with a mean difference of -1.000 mm (95% CI -1.309 to -0.691; p < 0.001) and a very large effect size (d = -2.612). Clinically, the digital group showed higher patient satisfaction with aesthetics and a shorter operation duration, while no difference in infraorbital nerve numbness was observed between the two groups. Based on the statistical and clinical findings of this study, a fully digital workflow provided a valuable approach for the management of zygomaticomaxillary complex fractures, optimizing aesthetic and functional rehabilitation.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.