A 4K 3D exoscope measured facial recess width with strong CT agreement

In 23 cochlear implant cases, exoscope-based measurements of facial recess width agreed strongly with preoperative CT measurements; cadaveric comparisons also showed good agreement, and reconstruction took about 2 seconds. The workflow was feasible but some cadaveric attempts failed, and the study did not establish measurement accuracy or show that the measurements change surgical decisions. Further testing is needed before their clinical value is clear.

Journal
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery (Q1)
Published
16 November 2026
Study design
Prospective / inception cohort
Evidence level
Level 2, Moderate (CEBM 2b)
Authors
Chaoyue Zhao, Bo Gao, Wei Liu, Yaying Ta, Yang Zhou, Junhui Tang, et al.
PMID
43037709
DOI
10.1007/s00405-026-10740-9

Why clinicians should know about it

  • Picked for Anatomy (paper of the day, 17 November 2026): Cadaveric and clinical three-dimensional facial recess measurements

Abstract

PURPOSE: To evaluate the technical feasibility of 4K3D exoscope-based non-contact three-dimensional measurement of the facial recess and explore agreement with scale-calibrated two-dimensional ImageJ measurements in cadaveric specimens and preoperative CT measurements in patients undergoing cochlear implantation. METHODS: The system used in this study combined an AINNOVI-100 exoscope with SurgeReal 3D Studio. Cadaveric feasibility assessment and method comparison included 10 temporal bones from eight formalin-fixed cadaveric heads. Three-dimensional measurements were compared with scale-calibrated two-dimensional ImageJ measurements. The prospective single-center cohort included 23 patients undergoing cochlear implantation. Intraoperative measurements were compared with preoperative high-resolution computed tomography measurements for exploratory agreement using absolute-agreement intraclass correlation coefficients and Bland-Altman analysis. RESULTS: Cadaveric intraclass correlation coefficients ranged from 0.878 to 0.934. Mean model-generation time was 1.97 s, and the recorded workflow from reconstruction initiation to result storage lasted 46.07 s. 31 of 35 cadaveric measurement attempts were successful (88.6%), including 29 initial successes (82.9%); 4 attempts failed (11.4%). In the 23 clinical cases, agreement was strongest for facial recess width (intraclass correlation coefficient, 0.962). Angular limits of agreement were wider but remained within the stated ± 10° comparison margin in both cohorts. CONCLUSION: This study supports the feasibility of obtaining non-contact quantitative measurements of the exposed facial recess using a 4K3D exoscope. The observed agreement, particularly for facial recess width, and the short reconstruction and measurement times support further evaluation of this workflow for intraoperative anatomical documentation. Future studies should establish three-dimensional measurement accuracy and reproducibility and examine how the resulting information contributes to surgical decision-making.