Skip to main content

Accuracy of anatomical landmarks for the pelvic C-clamp: a three-dimensional CT imaging study

Journal
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie (Q1)
Published
12 November 2026
Study design
Unclassified
Evidence level
Level 5, Expert Opinion (CEBM 5)
Authors
Kanyakorn Riewruja, Pannathorn Itdhiamornkulchai, Numphung Numkarunarunrote, Yuda Chongpison, Chavarin Amarase, Sanzhar Artykbay, et al.
PMID
43018651
DOI
10.1007/s00590-026-05010-7

Why clinicians should know about it

  • Picked for Anatomy (paper of the day, 15 November 2026): 3D CT tests pelvic C-clamp landmarks and placement safety

Abstract

PURPOSE: To evaluate the accuracy of three commonly used anatomical landmarks for pelvic C-clamp pin insertion using three-dimensional (3D) CT imaging. METHODS: From a cohort of patients undergoing CT angiography of the lower extremities, 3D bony reconstruction images were created. Three commonly used anatomical insertion landmarks-the intersection points described by Ganz et al. (point A), by Pohlemann et al. (point B), and by the DePuy Synthes Pelvic C-Clamp surgical guide (point C)-were drawn on the 3D CT reconstruction images, and their relationship with the SI joint surface was recorded. We additionally stratified landmark accuracy by SI joint surface morphology. Patient-level clustering was accounted for using generalized estimating equations (GEE). RESULTS: A total of 101 hemipelves were obtained from 51 patients (36 men and 15 women; mean age 61.56 years). In terms of accuracy, point A demonstrated 69.31% of points overlying the SI surface, recorded as 'IN', and 22.77% overlying the central quadrant of the SI surface, recorded as 'CENTER'; point B demonstrated 68.32% and 21.78%; and point C demonstrated 56.44% and 9.90%, respectively. Point A demonstrated significantly higher odds than point C for both 'IN' (OR 1.74, 95% CI 1.03-2.95; p = 0.0377) and 'CENTER' placement (OR 2.69, 95% CI 1.07-6.76; p = 0.0358), whereas the corresponding differences for point B did not reach statistical significance ('IN': OR 1.67, 95% CI 0.99-2.79; p = 0.0534; 'CENTER': OR 2.54, 95% CI 0.91-7.10; p = 0.0761). Anterior misplacement was the most frequent type of malposition for all insertion points. Sacral morphology did not statistically influence the accuracy of any landmark. CONCLUSION: Point A demonstrated the highest observed imaging-defined accuracy and significantly higher odds of both IN and CENTER placement than point C after accounting for patient-level clustering. Point B showed higher odds than point C for both outcomes, but these differences did not reach statistical significance. These findings should be interpreted as bone-referenced, imaging-based estimates rather than direct evidence of biomechanical superiority or clinical safety. Fluoroscopic guidance remains advisable when clinically feasible. LEVEL OF EVIDENCE: III Diagnostic Level III.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.