Left Atrial Appendage Closure in Patients Considered Unsuitable for Oral Anticoagulation: Randomized Outcomes Through 5 Years in ASAP-TOO
In brief
Watchman closure saw 7.8% stroke or embolism versus 11.4%, but trial was underpowered
In patients considered unsuitable for anticoagulants, stroke or systemic embolism occurred in 7.8% with left atrial appendage closure and 11.4% with control treatment through up to 5 years. The trial stopped early and had too few events to establish whether closure reduced risk; major bleeding was more frequent with closure, particularly during the first 3 months.
- Journal
- Journal of the American College of Cardiology (Q1)
- Published
- 31 October 2026
- Study design
- Randomized controlled trial
- Evidence level
- Level 1, High (CEBM 1b)
- Authors
- Vivek Y Reddy, Maurice Buchbinder, Devi G Nair, Ziad F Issa, Timothy R Betts, Boris Schmidt, et al.
- PMID
- 43018511
- DOI
- 10.1016/j.jacc.2026.10.007
Why clinicians should know about it
- Picked for Cardiology and Cardiovascular Medicine (top studies of the week, 15 November 2026): Randomized long-term evidence for appendage closure when anticoagulation unsuitable
Abstract
BACKGROUND: Oral anticoagulation (OAC) use in atrial fibrillation is suboptimal due to real or perceived bleeding risks. Left atrial appendage closure (LAAC) is an alternative to OAC, but pivotal trials used OAC comparators. OBJECTIVES: The study sought to assess the long-term safety and effectiveness of LAAC in patients deemed unsuitable for OAC. METHODS: The ASAP-TOO trial was a multinational randomized trial of patients with atrial fibrillation, CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category) score ≥2, and OAC unsuitability; target enrollment was 888 patients. Patients were assigned 2:1 to LAAC with a Watchman device or control treatment-single antiplatelet therapy or no therapy. Device patients received dual antiplatelet therapy for 3 months and aspirin through 12 months. The primary effectiveness endpoint was ischemic stroke or systemic embolism; the primary safety endpoint was death, ischemic stroke, systemic embolism, or 7-day device/procedure-related events requiring major intervention. RESULTS: Enrollment stopped early because of slow accrual, accentuated by the COVID-19 pandemic: only 481 patients were randomized (320 LAAC, 161 control treatment) and withdrawal was significant (7.8% LAAC, 24.2% control treatment), with disparate follow-up durations (median 876 days and 440.1 total patient-years of follow-up for control patients; median 1,768 days and 1,154.6 total patient-years of follow-up for LAAC patients), reducing statistical power. Patients were 75 ± 8 years of age, the CHA2DS2-VASc score was 4.6 ± 1.7, and 34% had prior intracranial/subdural hemorrhage. Implantation success was 97.8%. Only 31 of the 101 planned primary effectiveness events occurred, fewer than the 34 events required to trigger the first planned interim analysis. The primary safety endpoint occurred in 1.0% of implant-attempted patients, meeting the prespecified performance goal (P < 0.0001); there were 3 pericardial effusions requiring intervention. At up to 5 years, ischemic stroke or systemic embolism occurred in 7.8% with LAAC and 11.4% with control treatment (HR: 0.73; 95% CI: 0.35-1.52; P = 0.39). Major bleeding was 22.1% with LAAC and 15.7% with control treatment (HR: 1.64; 95% CI: 0.96-2.81; P = 0.067), concentrated during the first 3 months. In an exploratory analysis, disabling/fatal stroke was nominally less frequent with LAAC (2.2% vs 5.7%; HR: 0.32; 95% CI: 0.10-1.05). CONCLUSIONS: In this prematurely terminated and underpowered trial, LAAC implantation was successful, with acceptable safety. Long-term estimates with LAAC were numerically favorable for thromboembolism but imprecise, while early bleeding was increased with the mandated antiplatelet regimen. These findings should be interpreted as exploratory and integrated with contemporary evidence and shared decision making. (Assessment of the WATCHMAN Device in Patients Unsuitable for Oral Anticoagulation [ASAP-TOO]; NCT02928497).
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.