Ground-glass-adjusted CT method identified solid nodule pixels with an AUC of 0.85

In 170 surgically resected lung nodules, a threshold adjusted to each nodule's ground-glass attenuation best distinguished expert-annotated solid pixels, with an area under the curve of 0.85. Lesion-adaptive methods performed better overall than fixed thresholds, but the study used one center and scanner; external validation is needed before clinical use.

Journal
Translational lung cancer research (Q1)
Published
29 September 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Yuhao Chen, Nan Chen, Yuhuan Ye, Han Zhang, Wanting Xia, Kunhao Wu, et al.
PMID
42999425
DOI
10.21037/tlcr-2026-0841

Why clinicians should know about it

Abstract

BACKGROUND: Solid-component assessment in pulmonary ground-glass nodules (GGNs) remains subjective, and no universally accepted computed tomography (CT) attenuation threshold exists. Fixed cutoffs may not account for inter-lesion variation in baseline ground-glass opacity (GGO) attenuation. We aimed to develop and internally validate lesion-adaptive quantitative CT definitions of the solid component using three-dimensional pixel-level expert annotations as the imaging reference standard. METHODS: This retrospective single-center methodological study included 170 unique patients with 170 surgically resected stage I lung adenocarcinoma-spectrum GGNs from March 2015 through July 2018 and each patient contributed one target lesion. All examinations were acquired on the same 256-row CT scanner, and venous-phase 1-mm images reconstructed with medium-strength deep learning image reconstruction were used for analysis. Each lesion was independently annotated by at least two experienced thoracic surgeons, with Dice-based adjudication and senior review. Patients were randomly allocated to training (n=120) and internal validation (n=50) cohorts. Nine prespecified study methods and three literature-based fixed thresholds were evaluated at pixel and lesion levels. RESULTS: The training and validation cohorts had median lesion sizes of 1.2 and 1.3 cm and median annotated solid-component proportions of 0.324 and 0.319, respectively. The GGO mean plus ratio method achieved the highest area under the receiver operating characteristic (ROC) curve [AUC, 0.848; 95% confidence interval (CI): 0.841-0.856], with sensitivity of 0.732, specificity of 0.815, and F1/Dice of 0.760. The GGO mean plus difference method yielded the highest lesion-level coefficient of determination (R2, 0.744; 95% CI: 0.499-0.889), whereas the ratio method yielded the lowest root mean square error (RMSE, 0.105) and mean absolute error (MAE, 0.088). Pairwise DeLong testing showed no statistically significant AUC difference among the three top-performing GGO-referenced methods. CONCLUSIONS: In this single-center internal validation study, lesion-adaptive GGO-referenced methods showed more favorable overall pixel-level discrimination and lesion-level agreement than universal fixed thresholds or lesion-summary estimators. These rules should be considered developmental quantitative methods and require multicenter external validation across CT platforms and reconstruction protocols before routine clinical use.