Skip to main content

Comparison of Two Deep Learning Models and Their Combination for 1-year Lung Cancer Detection in Two Screening Cohorts

Journal
Radiology. Cardiothoracic imaging (Q1)
Published
1 December 2026
Study design
Unclassified
Evidence level
Level 5, Expert Opinion (CEBM 5)
Authors
Anthony P Reeves, Mohammad Mozafary, Ali Hashemi, Kyle Atlas, Chenyu Zhang, Thomas Atlas, et al.
PMID
42986194
DOI
10.1148/ryct.260087

Why clinicians should know about it

Abstract

Purpose To evaluate the performance of Sybil, a Medical Open Network for Artificial Intelligence (MONAI)-based nodule model, and their combination for 1-year lung cancer detection in two screening cohorts: the National Lung Screening Trial (NLST) and the Pamplona International Early Lung Cancer Action Program (P-IELCAP). Materials and Methods Baseline low-dose CT (LDCT) examinations from the NLST and the P-IELCAP were analyzed. A prespecified OR-stacked composite model combining Sybil, a MONAI-based nodule model, and a safety-net rule (MONAI-detected nodule > 6 mm with detection confidence > 0.95) was developed and evaluated for 1-year lung cancer detection. Model discrimination was assessed by using area under the receiver operating characteristic curve (AUC), and operating-point performance metrics were calculated. Results A total of 5110 baseline LDCT examinations were analyzed, including 2343 from NLST and 2767 from P-IELCAP, with 65 lung cancers diagnosed within 1 year. Mean age, mean pack-years, and percentage of female participants were 61.6 years ± 5.1 (SD), 57.3 pack-years ± 24.8, and 39.4% (923 of 2343), respectively, in NLST and 56.0 years ± 9.5, 34.4 pack-years ± 21.5, and 28.6% (791 of 2767), respectively, in P-IELCAP. Lung cancer incidence (per 1000 person-years) was higher in NLST than in P-IELCAP (17.7 vs 8.7; P = .006). Mean Sybil 1-year lung cancer probabilities (scaled by 1000 for presentation) were also higher in NLST than in P-IELCAP (16.4 vs 9.9; P < .01). Sybil achieved an AUC of 0.93 in both cohorts, whereas the MONAI-based model achieved AUCs of 0.90 in NLST and 0.79 in P-IELCAP. The composite model missed two of 65 1-year lung cancers while correctly classifying 2731 of 4965 (55.0%) noncancer examinations as negative, yielding a sensitivity of 63 of 65 (96.9%) and a positive predictive value of 63 of 2297 (2.7%). Conclusion For 1-year lung cancer detection with LDCT, the composite AI model achieved high sensitivity while maintaining acceptable specificity. Keywords: Applications-CT, Thorax, Pulmonary, Sybil, MONAI, NLST, P-IELCAP, Lung Cancer, Low Dose Computed Tomography Supplemental material is available for this article. © RSNA, 2026.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.