Skip to main content

First Korean experience with shape-sensing robotic-assisted bronchoscopy integrated with mobile cone-beam CT: Results from the prospective ULSAN-ION study

In brief

Robotic bronchoscopy with cone-beam CT diagnosed 85% of nodules in Korean patients

In a prospective single-center Korean cohort, shape-sensing robotic bronchoscopy with mobile cone-beam CT produced a diagnosis for 119 of 140 peripheral lung nodules (85%); patient-level yield was 90.1%. Pneumothorax affected 4.5% of patients, and 2.7% needed chest tubes, while no severe airway bleeding occurred. Because this was a single-center study, how well the results generalize remains unknown.

Journal
Lung cancer (Amsterdam, Netherlands) (Q1)
Published
31 October 2026
Study design
Prospective / inception cohort
Evidence level
Level 2, Moderate (CEBM 2b)
Authors
Ganghee Chae, Chul Park, Jin Hyoung Kim, Seung Won Ra, Kwang Won Seo, Yangjin Jegal, et al.
PMID
42967372
DOI
10.1016/j.lungcan.2026.109674

Why clinicians should know about it

Abstract

INTRODUCTION: Shape-sensing robotic-assisted bronchoscopy (ssRAB) integrated with mobile cone-beam CT (mCBCT) has emerged as a promising platform for the diagnosis of peripheral pulmonary nodules (PPNs), with high diagnostic yield and low complication rates. However, no data have been reported in a Korean population. We evaluated the diagnostic yield and safety of ssRAB integrated with mCBCT in a Korean cohort. METHODS: This prospective, single-center cohort (the ULSAN-ION study) enrolled patients undergoing ssRAB with integrated mCBCT from July 2025 to April 2026 (ClinicalTrials.gov: NCT07057648). Diagnostic yield was assessed using the strict ATS/ACCP definition at the per-nodule and per-patient levels. RESULTS: A total of 111 patients with 140 PPNs were enrolled. Median age was 64.0 years (IQR, 55.5-69.5), and 51.4 % were male. Median nodule size was 14.0 mm (IQR, 10.0-19.2), and nodule morphology included solid (57.9 %), part-solid (28.6 %), and pure ground-glass opacity (13.6 %). A CT bronchus sign was absent in 70.7 % of nodules. mCBCT was performed in 88.6 % of nodules, with tool-in-lesion confirmation in 77.9 % and an overall tool-to-lesion rate of 99.1 %. Per-nodule diagnostic yield was 85.0 % (119/140) and per-patient diagnostic yield was 90.1 % (100/111). A malignant diagnosis was established in 75.7 % of patients, most commonly adenocarcinoma, and a specific benign diagnosis in 14.4 %. Pneumothorax occurred in 4.5 % of patients, with chest tube insertion required in 2.7 %. Airway bleeding (Nashville Grade ≥ 2) occurred in 1.8 %, with no Grade ≥ 3 events. CONCLUSION: This first prospective Korean experience demonstrates that ssRAB integrated with mCBCT achieves high diagnostic yield with an acceptable safety profile for PPN diagnosis.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.