Comparative Effectiveness and Safety of Energy Devices for Thyroidectomy: An Outcome-Specific Network Meta-Analysis of Randomized Controlled Trials

In brief

Harmonic devices cut postoperative bleeding odds by 44% versus conventional hemostasis

In a network meta-analysis of randomized trials, Harmonic devices also reduced operative time, blood loss, hospital stay, and odds of transient hypocalcemia and vocal cord nerve palsy compared with conventional hemostasis. LigaSure improved operative efficiency, but its other benefits were less consistent. The comparisons do not establish overall device superiority, so absolute benefits and device characteristics still matter.

Journal
Head & neck (Q1)
Published
27 October 2026
Study design
Systematic review / meta-analysis of RCTs
Evidence level
Level 1, High (CEBM 1a)
Authors
Do Hyun Kim, David W Jang, Se Hwan Hwang
PMID
42947529
DOI
10.1002/hed.70524

Why clinicians should know about it

  • Picked for Breast and Endocrine Surgery (paper of the day, 29 October 2026): Randomized-trial synthesis compares devices used in thyroidectomy

Abstract

BACKGROUND: We performed an outcome-specific network meta-analysis comparing contemporary energy devices in thyroidectomy. METHODS: Randomized controlled trials comparing conventional hemostasis with Harmonic, LigaSure, Thunderbeat, or other advanced energy devices during thyroidectomy were included. Frequentist random-effects network meta-analyses were performed per outcome, with treatments ranked by P-scores and consistency assessed via design-by-treatment interaction and node-splitting analyses. RESULTS: Compared to conventional hemostasis, Harmonic significantly reduced operative time (SMD, -1.88), blood loss (SMD, -2.29), drainage volume (SMD, -1.77), hospital stay (SMD, -0.74), transient hypocalcemia (OR, 0.61), transient recurrent laryngeal nerve palsy (OR, 0.63), and postoperative bleeding (OR, 0.56). LigaSure improved operative efficiency but showed less consistent recovery and safety benefits. Harmonic ranked highest across most outcomes. CONCLUSIONS: Harmonic showed the most favorable relative effects across the evaluated outcomes. However, these findings do not establish overall device superiority; selection should consider absolute benefits and device-specific characteristics.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app