Skip to main content

Suture-Button Fixation Provides a Statistically But Not Clinically Important Improvement in Function for Syndesmotic Injuries in Unstable Ankle Fractures: A Systematic Review and Network Meta-Analysis of Randomized Controlled Trials

In brief

Suture-button fixation adds 5 ankle-function points, below meaningful threshold

In 12 randomized trials involving 883 adults, suture-button fixation scored 5.2 points higher than a three-cortex screw on ankle function at one year, short of the 10-point threshold considered clinically important. Unplanned reoperations did not differ, and evidence certainty was low to very low; whether the small functional gain matters in practice remains unclear.

Journal
JB & JS open access (Q1)
Published
27 October 2026
Study design
Systematic review / meta-analysis of RCTs
Evidence level
Level 1, High (CEBM 1a)
Authors
Wayne Hoskins, Charles Gusho, Kevin Horner, Douglas Haase
PMID
42924391
DOI
10.2106/JBJS.OA.26.00303

Why clinicians should know about it

Abstract

BACKGROUND: No consensus exists on the optimal syndesmotic fixation for unstable ankle fractures. We compared strategies using a network meta-analysis (NMA) of randomized controlled trials (RCTs). METHODS: Seven databases and trial registers were searched through November 1, 2025 for RCTs of adults undergoing fixation of an ankle fracture with syndesmotic injury; quasirandomized and duplicate/follow-up reports were excluded. Interventions were grouped a priori as suture-button/dynamic fixation, metallic 3-cortex screw (reference), metallic 4-cortex screw, bioabsorbable screw, and no fixation. A frequentist random-effects NMA estimated mean differences (MD) for function (Olerud-Molander Ankle Score [OMAS] at 1 year, the outcome reported by the most trials; AOFAS) and odds ratios (OR) for malreduction and reoperation (primary definition excluding planned implant removal), with treatments ranked by P-score and effects interpreted against the minimal clinically important difference (MCID). Certainty was rated with a CINeMA-equivalent assessment. RESULTS: Twelve RCTs (883 patients) formed a connected network. For 1-year OMAS, suture-button fixation ranked highest (P-score 0.86; MD +5.2 points versus the 3-cortex screw; 95% CI, +1.1 to +9.2)-statistically significant but below the 10-point MCID-while the 4-cortex screw ranked lowest; heterogeneity was low (I2 = 10%) without inconsistency. The AOFAS did not differ between suture-button and the 3-cortex screw (MD 0.0; 95% CI, -4.5 to +4.5). Malreduction was lower with suture-button fixation (OR 0.26; 95% CI, 0.06-1.11; 0.27 [0.11-0.64] fixed-effect). Unplanned reoperation did not differ between constructs (suture-button OR 0.45; 95% CI, 0.17-1.16), whereas all-cause reoperation favored the suture-button and bioabsorbable constructs. Certainty of evidence was low to very low. CONCLUSIONS: Suture-button/dynamic fixation provides 1-year function at least equivalent to screws, with lower malreduction and fewer all-cause reoperations from avoiding routine implant removal. Functional differences are small and below the MCID, and certainty is low. LEVEL OF EVIDENCE: Therapeutic, Level I. See Instructions for Authors for a complete description of levels of evidence. REGISTRATION: PROSPERO CRD420251166994.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.