Skip to main content

Q-AortaECG: A Quantum-Inspired Multi-Agent 12-Lead ECG System for Early Triage of Acute Aortic Syndrome

In brief

ECG triage system detected 96% of acute aortic syndromes in testing

In a 700-patient locked test, Q-AortaECG identified 95.5% of confirmed acute aortic syndromes, but specificity was 72.1%, so false alarms remain a concern. In a reader study, assistance raised clinician sensitivity from 69.6% to 87.0%; silent-run alerts could have shortened time to the correct diagnostic pathway, but CT angiography and expert imaging remain the diagnostic standard.

Journal
IEEE journal of biomedical and health informatics (Q1)
Published
23 October 2026
Study design
Prospective / inception cohort
Evidence level
Level 2, Moderate (CEBM 2b)
Authors
Lu Yu, Guanyu Qiao, Xiaolang Jiang, Yifan Liu, Penghui Wang, Wen Xi, et al.
PMID
42912522
DOI
10.1109/JBHI.2026.3746586

Why clinicians should know about it

  • Picked for Health Informatics (paper of the day, 25 October 2026): Prospective silent-run and reader evaluation of ECG decision support
  • Picked for Emergency Medicine (paper of the day, 25 October 2026): ECG-based acute aortic syndrome triage targets a time-critical ED diagnosis

Abstract

Acute aortic syndrome (AAS) is a time-critical vascular emergency in which delayed recognition may occur because the presenting symptoms and electrocardiographic phenotypes often overlap with acute coronary syndrome, pulmonary embolism, pericarditis, and other emergency diagnoses. Computed tomographic angiography (CTA) remains the confirmatory standard, but the 12-lead electrocardiogram (ECG) is usually obtained earlier, is universally available at triage, and may carry distributed signatures of malperfusion, ischemia mimicry, autonomic stress, conduction delay, and hemodynamic compromise. We developed Q-AortaECG, a classically implemented quantum-inspired multi-agent ECG system that integrates multiscale waveform representations, specialist ECG agents, density-state uncertainty fusion, a variational-circuit style consensus layer, and a safety-gated multidisciplinary team-style report for early AAS triage. The system was evaluated in three suspected-AAS/CTA-evaluable cohorts comprising 1,251 patients, including 467 with CTA-, surgery-, or autopsy-confirmed AAS. Across 700 locked-test patients, Q-AortaECG achieved an area under the receiver operating characteristic curve (AUROC) of 0.881 (95% confidence interval (CI), 0.852-0.908), area under the precision-recall curve (AUPRC) of 0.743 (95% CI, 0.695-0.790), sensitivity of 0.955 (231/242; 95% CI, 0.920-0.977), specificity of 0.721 (330/458; 95% CI, 0.677-0.761), positive predictive value (PPV) of 0.643, and negative predictive value (NPV) of 0.968 at the prespecified high-sensitivity threshold. Performance remained consistent in external retrospective validation and prospective silent-run evaluation, although AUPRC decreased in the lower-prevalence prospective cohort. Ablation experiments supported the contributions of self-supervised ECG pretraining, agent specialization, density-matrix uncertainty fusion, and differential diagnosis modeling. In a counterbalanced paired reader study, Q-AortaECG assistance improved overall clinician sensitivity from 0.696 to 0.870 while preserving specificity (0.851 ver sus 0.846). In prospective silent-run analysis, counterfactual alerts would have advanced the median time to the correct diagnostic pathway from 187 to 61 minutes among initially unsuspected AAS presentations. These findings support ECG first, calibrated, safety-gated decision support as an early warning scaffold for AAS triage, while preserving CTA and expert imaging interpretation as the diagnostic standard.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.