Skip to main content

Procedural Complications and Implant Cutout of the SpineJack®-System in Thoracolumbar Vertebral Fractures: A Retrospective Analysis of 204 Implants from a Level-1 Trauma Center

Journal
Global spine journal (Q1)
Published
11 October 2026
Study design
Prospective / inception cohort
Evidence level
Level 4, Very Low (CEBM 4)
Authors
Julian Scherer, Magdalena Karner, Georg Osterhoff, Kai Sprengel, Hans-Christoph Pape
PMID
42859915
DOI
10.1177/21925682261497980

Why clinicians should know about it

  • Picked for Spine Surgery (paper of the day, 15 October 2026): Endplate cutout occurred in 7.8% of implants

Abstract

Study DesignRetrospective cohort study.ObjectivesImplant-related complications of SpineJack® stent-kyphoplasty, particularly endplate cutout, remain poorly characterized. This study determined the incidence of procedural complications, with a focus on cutout, and identified associated factors.MethodsAll patients treated with stand-alone SpineJack® stent-kyphoplasty at a level-1 trauma center (November 2014-December 2022) were retrospectively reviewed, excluding malignant fractures. In total, 204 implants were analyzed (129 OVFs, 75 VCFs). Intraoperative complications and postoperative endplate cutout, assessed on imaging after mobilization, were analyzed by fracture type, AO/OF classification, region and vertebral level.ResultsMean age was 64.9 years (SD 17.5); OVF patients were significantly older than VCF patients (74.3 vs 48.8 years, p<0.001). Vascular cement leakage occurred in 2 cases (1.0%); no technical failures or conversions were recorded. Cement leakage occurred in 18 implants (8.8%) and cutout in 16 (7.8%), neither differing by fracture type. Cutout incidence differed significantly across OF grades (p=0.018), though not after excluding the small OF1 subgroup (p=0.211) or in multivariable analysis (OR 1.03, p=0.918), suggesting limited power; cutout was not correlated with cement leakage or vertebral level.ConclusionsStand-alone SpineJack® stent-kyphoplasty is associated with infrequent vascular and cement-related complications. Endplate cutout (7.8%) was numerically more frequent in severely collapsed osteoporotic (OF4) fractures, but this association was not robust to sensitivity or multivariable analysis, consistent with limited power rather than a true absence of effect; no cutout event in this cohort had a demonstrated clinical consequence. Prospective, adequately powered study is needed to confirm this association.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.