Skip to main content

Biologic Graft Augmentation Is Associated With Lower Retear Rates and Greater Tendon Thickness Compared With Arthroscopic Rotator Cuff Repair Without Augmentation: A Systematic Review and Meta-analysis of Randomized Controlled Trials

Journal
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association (Q1)
Published
8 October 2026
Study design
Systematic review / meta-analysis of RCTs
Evidence level
Level 1, High (CEBM 1a)
Authors
Vraj Amin, Kassem Ghayyad, Olamide Oshikoya, Daniel Goltz, G Russell Huffman
PMID
42850980
DOI
10.1002/arj.70619

Why clinicians should know about it

Abstract

PURPOSE: To perform a systematic review and meta-analysis of Level I and II randomized studies evaluating biologic graft augmentation in arthroscopic or arthroscopic-equivalent rotator cuff repair. METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a systematic literature search was conducted in PubMed, Scopus, Embase, and Cochrane databases. Randomized controlled trials comparing the use of a biologic graft augmentation in adjunct to standard arthroscopic repair were included. A minimum clinical follow-up of greater than 1 year was required for inclusion. Outcome measures included retear rate, tendon thickness, American Shoulder and Elbow Surgeons score, Constant score, and the University of California Los Angeles score. Random-effects models were used to calculate mean differences and 95% confidence intervals. RESULTS: From our literature search, 9 randomized controlled trials consisting of 556 patients met criteria for inclusion in the meta-analysis. The use of biologic graft augmentation showed a significant reduction in retear rates (risk ratio = 0.31; confidence interval: [0.22, 0.45]; P < .00001) and a significant increase in tendon thickness at final follow-up (mean difference: 1.20 mm; confidence interval [1.14, 1.26]; P < .00001). Meta-analysis also revealed a significant increase between preoperative and postoperative American Shoulder and Elbow Surgeons and Constant score and a nonsignificant increase between preoperative and postoperative University of California Los Angeles score. CONCLUSIONS: Biologic graft augmentation in arthroscopic or arthroscopic-equivalent rotator cuff repair was associated with lower retear rates and greater tendon thickness. Clinical outcome improvement was less consistent across reported patient-reported measures, and interpretation should account for heterogeneity in graft type and outcome reporting. LEVEL OF EVIDENCE: Level II, systematic review and meta-analysis of Level I and II studies.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.