Less Invasive Surfactant Administration Using Video Laryngoscope to Decrease Pain in Neonates: A Randomized Controlled Trial
- Journal
- Pediatric pulmonology (Q1)
- Published
- 1 September 2026
- Study design
- Randomized controlled trial
- Evidence level
- Level 1, High (CEBM 1b)
- Authors
- Mude Praneetha, Tapas Som, Pankaj Mohanty, Tanushree Sahoo, Usha Devi R
- PMID
- 42639729
- DOI
- 10.1002/ppul.71808
Why clinicians should know about it
- Picked for Neonatology (top studies of the week, 30 August 2026): RCT of video vs conventional laryngoscope for LISA surfactant
Abstract
OBJECTIVES: To assess whether the use of video laryngoscope, when compared to conventional laryngoscope decreases pain (assessed by Faceless Acute Neonatal Pain Scale) in preterm neonates while administering surfactant by LISA. METHODS: Preterm neonates < 35 weeks requiring FiO2 > 0.3 on CPAP pressure of at least 6 cm of H2O were administered surfactant by LISA technique either by video laryngoscope (Intervention) or conventional laryngoscope (Control). Faceless Acute Neonatal Pain Scale was used to determine pain 5 min before the procedure, immediately, 5 min, and 10 min after the procedure. The primary outcome was severity of pain; secondary outcomes were time taken to complete the procedure, number of attempts, incidence of IVH, and adverse events during the procedure. RESULTS: In total, 42 neonates of < 35 weeks gestation with comparable baseline demographics were randomized into 2 groups. The median (IQR) FANS score immediately post-procedure in the intervention arm was 2 (2-4) versus 2 (1-4) in the control arm, p = 0.79. There was no statistical difference in the secondary outcomes studied. CONCLUSION: The two groups had no difference in the pain score. The pain experienced by neonates during the LISA procedure was moderate and of short duration and it did not depend on the type of laryngoscope used. Moderate pain during the procedure can be managed with nonpharmacological measures; thereby, the use of sedatives or analgesics can be avoided, which might be of concern. There was no difference in the number of attempts or in time taken to complete the procedure when performed by neonatologists experienced in using conventional laryngoscopes compared to video laryngoscopes. TRIAL REGISTRATION: Clinical Trial Registry of India: CTRI/2022/09/045204 on 05.09.2022.
Abstract as published, via PubMed.
For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.