Skip to main content

Prophylactic Surgical Left Atrial Appendage Closure in Bioprosthetic Aortic Valve Replacement: Short-Term Outcomes of Randomized Controlled LAA-CLOSURE Trial

Journal
Journal of the American Heart Association (Q1)
Published
20 August 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Tuomas Kiviniemi, Frank Halfwerk, Juan Bustamante Munguira, Igor Zindovic, Markus Malmberg, Christian Olsson, et al.
PMID
42622223
DOI
10.1161/JAHA.125.046654

Why clinicians should know about it

  • Picked for Surgery (top studies of the week, 23 August 2026).

Abstract

BACKGROUND: Surgical closure of the left atrial appendage (LAA) reduces stroke risk in patients with atrial fibrillation (AF) undergoing cardiac surgery. We evaluated the safety and efficacy of prophylactic LAA closure during bioprosthetic surgical aortic valve replacement in patients without prior AF. METHODS: In this investigator-initiated, academic, randomized, open-label, multicenter LAA-CLOSURE (Left Atrial Appendage CLOSURE for the Prevention of Thromboembolisms in Patients Undergoing Aortic Bioprosthesis Surgery) trial, 921 patients without prior AF undergoing bioprosthetic surgical aortic valve replacement with or without concomitant surgery were randomized and 904 patients included in the modified intention-to-treat analysis (prophylactic LAA closure, n=445; or usual care, n=459). Median age was 73 years (interquartile range, 69-76), 34.8% were women, and 49% had concomitant coronary artery disease. The primary end point was a composite of cardiovascular death, stroke, or systemic embolism at 30 days. RESULTS: The primary end point occurred in 10 of 434 (2.2%) patients in the LAA closure group and 14 of 452 (3.1%) patients in the control group; however, the treatment effect changed direction at ≈7 days. In the time-split Cox regression model, hazard ratios were 2.4 (95% CI, 0.62-9.4; P=0.20) between 0 and 7 days and 0.29 (95% CI, 0.080-1.0; P=0.056) between 7 and 30 days. No closure-related serious complications or differences in bleeding were observed. Postoperative AF occurred in 205 of 445 (46.1%) versus 184 of 459 (40.1%) patients (relative risk, 1.1 [95% CI, 0.99-1.3]; P=0.07), and AF at discharge in 40 of 445 (9.2%) versus 34 of 459 (7.7%) patients (relative risk, 1.2 [95% CI, 0.77-1.8]; P=0.44), in the closure and control groups, respectively. CONCLUSIONS: Prophylactic LAA closure during bioprosthetic surgical aortic valve replacement was safe and did not increase bleeding. REGISTRATION: URL: clinicaltrials.gov; Unique Identifier: NCT02321137.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.