Skip to main content

Validation of an Automated Artificial Intelligence-Driven Planner for Transcatheter Aortic Valve Replacement

Journal
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (Q1)
Published
5 August 2026
Study design
Unclassified
Evidence level
Level 5, Expert Opinion (CEBM 5)
Authors
Mark M P van den Dorpel, Lucas Uchoa de Assis, Jenna van Niekerk, Sophie Deckx, Matthew Sherman, Janelle Schrot, et al.
PMID
42554293
DOI
10.1002/ccd.70785

Why clinicians should know about it

  • Picked for Anatomy (paper of the day, 6 August 2026): High-quality evidence in a top journal

Abstract

BACKGROUND: Preprocedural planning with multislice computed tomography (MSCT) is an essential prerequisite for successful transcatheter aortic valve replacement (TAVR). However, preprocedural planning is time-consuming and may contain clinically meaningful interobserver variability. Artificial intelligence (AI) based automated planning methods may provide anatomical MSCT measurements while reducing the time load required for the analysis. Previous studies on the validation of AI-based TAVR planning methods excluded anatomical variants or lacked data on actual TAVR prosthesis size agreement. Mimics for TAVR (Materialise, Leuven, Belgium) is a new, AI-driven TAVR planning platform based on patient-specific 3D anatomical models and automated measurements through a web-based user interface. AIMS: To validate the Mimics for TAVR planning tool in clinical practice. METHODS: Key planning assessments were performed on pre-TAVR MSCT datasets using Mimics for TAVR and a commercially available semi-automated software package. Agreement between the two planning methods was assessed using intraclass correlation coefficients and Bland-Altman plots. RESULTS: A total of 126 consecutive patients (mean age 80 [74-85]; 56% male) who underwent MSCT as part of their TAVR work-up were included. Mimics for TAVR derived measurements showcased high accuracy and excellent agreement for the area of the aortic annulus (mean error ± SD: -1.9 ± 3.3%, ICC: 0.976 [95% CI: 0.966-0.984]), left ventricular outflow (-2.7 ± 3.8%, ICC: 0.970 [0.957-0.983]), sinotubular junction (-2.6 ± 4.2%, ICC: 0.953 [0.921-0.971]), coronary heights (LCA -3.5 ± 4.8%, ICC: 0.900 (0.859-0.928). RCA -3.9 ± 4.7%, ICC: 0.928 [0.898-0.949]) and membranous septum length (-5.0 ± 9.2%, ICC: 0.919 [0.880-0.940]). Mimics for TAVR assessment significantly reduced the time required for pre-TAVR analysis (1.03 ± 0.15 min vs. 9.55 ± 3.16 min per case, respectively (p = 0.001). CONCLUSION: The automated AI-driven Mimics for TAVR planner is an accurate alternative to existing semiautomated TAVR planning platforms and may enhance overall workflow efficiency.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.