Skip to main content

Impact of Aortic Annulus Size on Outcomes After Aortic Valve Replacement: The PARTNER 3 Trial

Journal
JACC. Cardiovascular interventions (Q1)
Published
27 July 2026
Study design
Randomized controlled trial
Evidence level
Level 1, High (CEBM 1b)
Authors
Mahesh V Madhavan, Michael J Mack, Philippe Pibarot, Rebecca T Hahn, Raj Makkar, Vinod H Thourani, et al.
PMID
42508852
DOI
10.1016/j.jcin.2026.05.023

Why clinicians should know about it

Abstract

BACKGROUND: There are limited studies comparing the impact of transcatheter aortic valve replacement (TAVR) vs surgical aortic valve replacement (SAVR) by annular size. OBJECTIVES: The aim of this post hoc analysis from the PARTNER (Placement of Aortic Transcatheter Valves) 3 trial was to assess the relationship between annular size and outcomes among patients with severe aortic stenosis (AS) who underwent TAVR or SAVR. METHODS: Low-risk patients with severe, symptomatic AS were randomized to TAVR using the balloon-expandable SAPIEN 3 valve or SAVR. Patients were stratified by computed tomographic angiography-derived aortic annular area (small, ≤430 mm2; large, >430 mm2). The primary endpoint was the composite of death, stroke, or rehospitalization. Interactions among annular size, treatment strategy, and adjudicated 5-year clinical outcomes were assessed. RESULTS: Of the 925 patients with available computed tomographic angiography-derived annular size, 293 had small and 632 had large aortic annuli, respectively. Median follow-up duration was 5.2 years (Q1-Q3: 5.0-6.0 years). Five-year rates of the primary endpoint were similar for TAVR and SAVR in the overall cohort, results that were consistent for patients with small (21.2% vs 31.0%; OR: 0.60; 95% CI: 0.35-1.02) and large (23.5% vs 25.5%; OR: 0.90; 95% CI: 0.62-1.29) annuli, without effect modification by annular size (P for interaction = 0.22). Rates of bioprosthetic valve failure were similar and low at 5 years, without effect modification by annular size. Five-year health status was also similar between treatment modalities across annulus strata (P for interaction = 0.12). CONCLUSIONS: TAVR with the SAPIEN 3 valve led to similar 5-year clinical and health status outcomes compared with SAVR, irrespective of annular size. (PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3]; NCT02675114).

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.