Skip to main content

Mechanical Circulatory Support for Complex High-Risk Indicated Percutaneous Coronary Intervention: Network Meta-Analysis of Randomized Trials

Journal
Journal of the American Heart Association (Q1)
Published
9 September 2026
Study design
Systematic review / meta-analysis of RCTs
Evidence level
Level 1, High (CEBM 1a)
Authors
Kamil Bujak, Claudio Laudani, Daniele Giacoppo, Marco Spagnolo, Maria Sara Mauro, Luigi Cutore, et al.
PMID
42714579
DOI
10.1161/JAHA.126.052609

Why clinicians should know about it

Abstract

BACKGROUND: Mechanical circulatory support (MCS) is increasingly used during complex high-risk indicated percutaneous coronary intervention, yet whether different support strategies improve clinical outcomes remains uncertain. We sought to compare the efficacy and safety of individual MCS strategies with standard care and with each other at short- and long-term follow-up. METHODS: This frequentist random-effects network meta-analysis included randomized trials of patients undergoing nonemergent complex high-risk indicated percutaneous coronary intervention and comparing percutaneous left ventricular assist devices, intra-aortic balloon pump, venoarterial extracorporeal membrane oxygenation, or standard care. The primary efficacy outcome was major adverse cardiovascular events. Secondary outcomes included death, myocardial infarction, stroke, or repeat revascularization, and periprocedural major adverse events. RESULTS: Eight trials (n=1856) were included. At 30 days, no MCS was associated with lower major adverse cardiovascular events compared with standard care, though percutaneous left ventricular assist devices (risk ratio [RR] 0.30, 95% CI 0.10-0.90) and intra-aortic balloon pump (RR 0.26, 95% CI 0.07-0.90) reduced periprocedural major adverse events. At a weighted mean of 10.8 months, no significant differences in major adverse cardiovascular events were observed with percutaneous left ventricular assist devices (incidence rate ratio 0.79; 95% CI 0.47-1.35), intra-aortic balloon pump (incidence rate ratio 0.89, 95% CI 0.52-1.54), or venoarterial extracorporeal membrane oxygenation (incidence rate ratio 1.47, 95% CI 0.64-3.40) compared with standard care. Consistently, no MCS strategy reduced death, myocardial infarction, stroke, or repeat revascularization. CONCLUSIONS: Among patients undergoing complex high-risk indicated percutaneous coronary intervention, MCS did not improve clinical outcomes, despite fewer periprocedural adverse events with percutaneous left ventricular assist devices and intra-aortic balloon pump. These findings do not support routine prophylactic use and suggest that MCS should be limited to selected patients.

Abstract as published, via PubMed.

View on PubMedFull text at the publisherOpen in the app

For healthcare professionals. The summary is generated by AI from the published abstract, and the evidence level is assigned automatically from the study design on the Oxford CEBM hierarchy. Neither is medical advice. Read the full paper before changing practice.