Ten Years of European Experience With Roadsaver Carotid Stent: A Systematic Review of Literature and Exploratory Meta-Analysis
In brief
Roadsaver carotid stent shows 1.6% stroke and 0.5% death at 30 days
In European practice, transfemoral carotid artery stenting with the Roadsaver dual-layer micromesh device resulted in a 1.6% stroke rate and 0.5% mortality within 30 days. pooled analyses found no clear advantage or disadvantage compared with first-generation stents or other micromesh devices, but the evidence is limited by few comparative studies and heterogeneous restenosis assessments. Larger randomized trials are needed to confirm any true device-specific benefit.
- Journal
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists (Q1)
- Published
- 17 July 2026
- Study design
- Systematic review / meta-analysis of RCTs
- Evidence level
- Level 1, High (CEBM 1a)
- Authors
- Giovanni Mastrangelo, Giuseppe Di Martino, Antonino Marzullo, Vincenzo Palazzo, Pierluigi Di Sebastiano
- PMID
- 42464753
- DOI
- 10.1177/15266028261453269
Why clinicians should know about it
- Picked for Family Practice (top studies of the week, 19 July 2026).
- Picked for Anatomy (top studies of the week, 19 July 2026): High-quality evidence in a top journal
- Picked for Cardiology and Cardiovascular Medicine (top studies of the week, 19 July 2026).
- Picked for Neurology (clinical) (top studies of the week, 19 July 2026).
- Picked for Radiology, Radiation Oncology, Nuclear Medicine, Medical Physics and Imaging (top studies of the week, 19 July 2026): Systematic review of Roadsaver carotid stent outcomes
- Picked for Surgery (top studies of the week, 19 July 2026).
Abstract
BACKGROUND: Dual-layer micromesh (DLMM) carotid stents were developed to enhance plaque scaffolding and reduce peri-procedural embolization during carotid artery stenting (CAS). Although Roadsaver is widely used in contemporary European practice, comparative evidence against first-generation stents (FGSs) and other DLMM devices remains limited. This study systematically reviews the European experience with Roadsaver and performs an exploratory meta-analysis of 30-day clinical outcomes and in-stent restenosis (ISR). METHODS: A systematic search of PubMed, Embase, and Medline identified European studies published between January 1, 2014 and December 31, 2024 reporting transfemoral CAS using the Roadsaver stent. Adult patients with extracranial, de novo carotid stenosis-symptomatic or asymptomatic-were included. Comparative analyses were limited to studies reporting paired outcomes for Roadsaver versus FGSs or C-Guard. Primary endpoints were 30-day stroke and death; the secondary endpoint was ≥50% ISR at approximately 12 months, as defined by each study. Pooled effects were calculated using Peto odds ratios with random-effects DerSimonian-Laird models. RESULTS: Twenty-two studies comprising 3539 Roadsaver procedures were included in the qualitative review; 5 studies met criteria for quantitative pooling. Across all studies, 30-day stroke and death occurred in 1.6% and 0.5% of patients, respectively. Meta-analysis showed no statistically significant differences in 30-day stroke or death between Roadsaver and FGSs, with low heterogeneity. In-stent restenosis comparisons similarly demonstrated no significant differences between Roadsaver and FGSs or between Roadsaver and C-Guard; however, ISR analyses were limited by marked heterogeneity in definitions, imaging modalities, and follow-up timing. CONCLUSIONS: Roadsaver DLMM stenting in European practice is associated with low 30-day stroke and death rates. Exploratory pooled analyses did not identify significant differences between Roadsaver and FGSs or between DLMM devices; however, the small number of comparative studies, variability in ISR assessment, and predominantly observational evidence base substantially limit the certainty of these findings. Larger, rigorously designed comparative studies, and randomized trials are needed to determine whether clinically meaningful differences exist between carotid stent platforms.Clinical impactIn this paper, transfemoral CAS with the Roadsaver dual-layer micromesh stent was associated with low 30-day stroke and death rates in European practice. Comparative analyses did not demonstrate significant differences versus first-generation stents or between DLMM devices; however, the observed safety profile, combined with mechanistic data on enhanced plaque scaffolding and embolic protection, supports the use of Roadsaver in routine CAS, including complex anatomies. These findings reinforce DLMM technology as a contemporary standard option rather than an experimental alternative, while underscoring the need for standardized ISR assessment and adequately powered randomized trials to guide device selection in carotid revascularization.
Abstract as published, via PubMed.